工业除尘设备运用时的注意事项:
1、灰斗、过滤室筒体、洁净室各入孔门、防爆门、察看孔等各法兰间应嵌入密封填料拧紧螺栓,避免漏气。
2、花板梯形孔应与下托架上的响应定位圈垂直,避免放入框架滤袋后上倾斜漏气。
3、反吹旋臂传念头构装置时要留意上下垂直,旋臂反转平面与框架导口上平面平行,且坚持2-4MM间隔,转变要灵敏。
4、顶盖上后,应先试其扭转能否灵敏。顶盖与洁净室外圈连接处使用橡胶密封,顶盖下应是密封性。
5、滤袋距架外面套上滤袋,袋口与导口用压条压紧,避免漏气,然后小心刺进花板中,(留意不要使滤袋划破或划伤)尾端锥销刺进下托架相应的定位圈中,在上部导口框架下面放槽胶圈后用压板,斜销压紧。
6、运转进程中各传动部件应按期注油,应按期检查反吹风旋臂能否正常,反吹风自控系统应按期检查,避免毛病。按期泊车检查各滤袋,发现滤袋有破损,应及时更换滤袋。
HY车间除尘设备
The matters needing attention in the application of industrial dust removal equipment are:
1, ash hopper, filter chamber cylinder, cleanroom entry door, explosion proof door, inspection hole and other flanges should be inserted into the sealing packing to tighten the bolts to avoid leakage.
2. The trapezoidal hole of the flower plate should be perpendicular to the response locating ring on the lower bracket, so that the air leakage of the trapezoidal hole on the lower bracket can be avoided.
3, the reverse blow - up arm of the idea structure device should pay attention to the upper and lower vertical, the reversal plane of the spiral arm parallel to the plane of the frame guide, and adhere to the 2-4MM interval, the change is sensitive.
4, after the top cover, we should first test whether the torsion is sensitive. The top cover and the outer ring of the clean room are sealed with rubber. The sealing under the top cover should be sealed.
5. The filter bag is covered with a filter bag outside the frame. The bag and guide mouth are pressed tight to avoid air leakage. Then carefully stab into the flower plate. (pay attention not to break or scratch the filter bag). The tail end cone pin is inserted into the corresponding positioning ring of the lower bracket, and then the slot rubber ring is pressed under the upper guide frame with the pressure plate and the slant pin is pressed tightly.
6, in the process of the operation of the transmission parts should be scheduled to oil, it should be scheduled to check whether the counter blow air arm is normal, the anti blowing system should be checked regularly to avoid the fault. Check the filter bags on time and find that the filter bags are damaged. Replace the filter bags in time.